Back to top
08045476282
Send SMS    Call Me Free Send Inquiry
Double Ended Beam Load Cell
Double Ended Beam Load Cell

Double Ended Beam Load Cell

Price 14000 INR/ Unit

MOQ : 1 Unit

Double Ended Beam Load Cell Specification

  • Application
  • Tensile testing
  • Voltage
  • 220-440 Volt (v)
  • Material
  • Alloy Steel
  • Usage
  • Industrial
  • Product Type
  • Double Ended Beam Load Cell
  • Color
  • Silver
 

Double Ended Beam Load Cell Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Payment Terms
  • Cash Advance (CA)
  • Supply Ability
  • 100 Units Per Month
  • Delivery Time
  • 7 Days
  • Main Domestic Market
  • All India
 

About Double Ended Beam Load Cell

Double Ended Beam Load Cell is used to measure compressive forces. This type of load cell is a variation of the shear beam load cell, normally rated for higher loads. In double-shear beam load cells, the force acts on the centre of the device. This makes double-shear beam load cells less sensitive to uneven loading. Double Ended Beam Load Cell is secured at both ends with load applied to the centre of the beam. These are secured at one end with the load applied to the opposite end. It is also used for a wide range of applications including floor scales, and hopper scales.

Product details

Application

Tensile testing

Brand

ADI

Capacity

100 Ton

Compensated Temperature Range

-10 to +40 Deg C

Creep Error (30 minutes)

+/- 0.03% FS

Features

Enviromentally protected

Ingress Protection

IP68

Input Resistance

770 +/- 20 Ohms

Insulation resistance at 50V DC

>= 1000 M Ohm

Material

Alloy Steel

Maximum Excitation Voltage

15V DC

Maximum Safe Overload

150% FS

Model

70210

Operating Temperatue Range

-20 to +70 Deg C

Output Resistance

700 +/- 7 Ohms

Output Sensitivity(FS)

3.0 +/- 0.003 mV/V

Recommended Excitation Voltage

5 to 15V DC

Temperature Effect on Output

+/-0.0015% FS/DegC

Temperature Effect on Zero

+/-0.002% FS/DegC

Type

Double Ended Shear Beam

Ultimate Safe Overload

300% FS

Zero balance

+/- 1% FS

FAQ

1. What is a double ended beam load cell?

Ans - A force transducer known as a double ended beam load cell detects the strain caused by two opposing forces acting on a beam. The load cell receives the force and outputs an electrical signal proportionate to the applied force.

2. What kinds of uses can a double terminated beam load cell be put to?

Ans - Many industrial and laboratory applications, including test stands, hopper scales, tension/compression cells, compression machines, and various other technical applications needing accurate measurement of load force, are well-suited for the use of double ended beam load cells.

3. How do double ended beam load cells differ from single ended beam load cells?

Ans - High accuracy, repeatability, and stability are offered by double ended beam load cells for a variety of loads. While single-ended beam load cells can only detect tension, its design enables higher resolution of both tension and compression forces.

4. What are double ended beam load cells' drawbacks?

Ans - Double ended beam load cells' restricted capacity and more complicated design are their principal shortcomings. They can only support extremely restricted ranges of forces due to the double ended beam arrangement, and their design necessitates appropriate setup and calibration for optimum operation.

5. What kinds of double ended beam load cells are there?

Ans - Both analogue and digital double ended beam load cells are available. Digital load cells are better suited for usage in laboratories and in industry than analogue load cells since they provide a digital output signal instead of an analogue one. Additionally equipped with integrated communication modules, digital load cells are simpler to integrate into distributed systems.



High-Performance Industrial Load Cell

Designed specifically for tough industrial environments, the Double Ended Beam Load Cell combines resilience with precision. Its alloy steel construction ensures long-lasting operation, while the voltage compatibility (220-440 V) supports diverse testing setups. Whether in research labs or factory floors, this load cell delivers reliable results during critical tensile testing processes.


Expert Manufacturing and Service in India

Our expertise as a manufacturer, service provider, and supplier in India guarantees top-quality load cells tailored for industrial needs. With meticulous attention to detail, we deliver equipment that meets stringent standards. Our support staff is always available to assist with installation, calibration, and after-sales service, ensuring customers get the most out of their investment.

FAQ's of Double Ended Beam Load Cell:


Q: How is the Double Ended Beam Load Cell used in industrial tensile testing?

A: The Double Ended Beam Load Cell is integrated into tensile testing machines to measure the force applied to materials. It accurately captures tension values, enabling users to evaluate material strength and performance under stress.

Q: What benefits does the alloy steel construction provide?

A: Alloy steel ensures exceptional strength, wear resistance, and a high load-bearing capacity. This durability translates into reliable data collection and a longer service lifespan, even in demanding industrial environments.

Q: When should I consider using this load cell for my tensile testing process?

A: You should use this load cell when accurate force measurement and durability are critical, particularly for industrial applications involving large or repetitive loads in tensile testing.

Q: Where is this load cell manufactured and whom can I contact for support?

A: This load cell is manufactured in India by an established provider specializing in industrial equipment. For assistance, you can reach out to our customer service team, who are available for installation guidance, calibration, and ongoing support.

Q: What is the process for installing and calibrating this load cell?

A: Installation involves securely mounting the load cell onto the testing apparatus using provided hardware and electrical connections. Calibration is completed by applying known weights and adjusting the system output to ensure measurement accuracy, with our team available to assist at every step.

Q: How does the 220-440 V operating voltage benefit my testing application?

A: This broad voltage compatibility allows the load cell to be easily integrated into various industrial setups without extensive modifications, ensuring operational flexibility and consistent performance across different facilities.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Load Cells Category

Heavy Duty Load Cell

Heavy Duty Load Cell

Price 14000 INR / Piece

Minimum Order Quantity : 1 Piece

Usage : Industrial

Color : Silver

Product Type : Heavy Duty Load Cell

Voltage : 220440 Volt (v)

Shear Beam Load Cell

Shear Beam Load Cell

Price 12000 INR / Piece

Minimum Order Quantity : 1 Piece

Usage : Industrial

Color : Silver

Product Type : Shear Beam Load Cell

Voltage : 220440 Volt (v)

Compression Load Cell

Compression Load Cell

Price 14000 INR / Piece

Minimum Order Quantity : 1 Piece

Usage : Industrial

Color : Blue

Product Type : Compression Load Cell

Voltage : 220440 Volt (v)

Stainless Steel Load Cell

Stainless Steel Load Cell

Price 6500 INR / Piece

Minimum Order Quantity : 5 Pieces

Usage : Industrial

Color : Silver

Product Type : Stainless Steel Load Cell

Voltage : 220440 Volt (v)