Double Ended Beam Load Cell
Price 14000 INR/ Unit
Double Ended Beam Load Cell Specification
- Application
- Tensile testing
- Voltage
- 220-440 Volt (v)
- Material
- Alloy Steel
- Usage
- Industrial
- Product Type
- Double Ended Beam Load Cell
- Color
- Silver
Double Ended Beam Load Cell Trade Information
- Minimum Order Quantity
- 1 Unit
- Payment Terms
- Cash Advance (CA)
- Supply Ability
- 100 Units Per Month
- Delivery Time
- 7 Days
- Main Domestic Market
- All India
About Double Ended Beam Load Cell
Double Ended Beam Load Cell is used to measure compressive forces. This type of load cell is a variation of the shear beam load cell, normally rated for higher loads. In double-shear beam load cells, the force acts on the centre of the device. This makes double-shear beam load cells less sensitive to uneven loading. Double Ended Beam Load Cell is secured at both ends with load applied to the centre of the beam. These are secured at one end with the load applied to the opposite end. It is also used for a wide range of applications including floor scales, and hopper scales.
Product details
|
Application |
Tensile testing |
|
Brand |
ADI |
|
Capacity |
100 Ton |
|
Compensated Temperature Range |
-10 to +40 Deg C |
|
Creep Error (30 minutes) |
+/- 0.03% FS |
|
Features |
Enviromentally protected |
|
Ingress Protection |
IP68 |
|
Input Resistance |
770 +/- 20 Ohms |
|
Insulation resistance at 50V DC |
>= 1000 M Ohm |
|
Material |
Alloy Steel |
|
Maximum Excitation Voltage |
15V DC |
|
Maximum Safe Overload |
150% FS |
|
Model |
70210 |
|
Operating Temperatue Range |
-20 to +70 Deg C |
|
Output Resistance |
700 +/- 7 Ohms |
|
Output Sensitivity(FS) |
3.0 +/- 0.003 mV/V |
|
Recommended Excitation Voltage |
5 to 15V DC |
|
Temperature Effect on Output |
+/-0.0015% FS/DegC |
|
Temperature Effect on Zero |
+/-0.002% FS/DegC |
|
Type |
Double Ended Shear Beam |
|
Ultimate Safe Overload |
300% FS |
|
Zero balance |
+/- 1% FS |
FAQ
1. What is a double ended beam load cell?
Ans - A force transducer known as a double ended beam load cell detects the strain caused by two opposing forces acting on a beam. The load cell receives the force and outputs an electrical signal proportionate to the applied force.
2. What kinds of uses can a double terminated beam load cell be put to?
Ans - Many industrial and laboratory applications, including test stands, hopper scales, tension/compression cells, compression machines, and various other technical applications needing accurate measurement of load force, are well-suited for the use of double ended beam load cells.
3. How do double ended beam load cells differ from single ended beam load cells?
Ans - High accuracy, repeatability, and stability are offered by double ended beam load cells for a variety of loads. While single-ended beam load cells can only detect tension, its design enables higher resolution of both tension and compression forces.
4. What are double ended beam load cells' drawbacks?
Ans - Double ended beam load cells' restricted capacity and more complicated design are their principal shortcomings. They can only support extremely restricted ranges of forces due to the double ended beam arrangement, and their design necessitates appropriate setup and calibration for optimum operation.
5. What kinds of double ended beam load cells are there?
Ans - Both analogue and digital double ended beam load cells are available. Digital load cells are better suited for usage in laboratories and in industry than analogue load cells since they provide a digital output signal instead of an analogue one. Additionally equipped with integrated communication modules, digital load cells are simpler to integrate into distributed systems.
High-Performance Industrial Load Cell
Designed specifically for tough industrial environments, the Double Ended Beam Load Cell combines resilience with precision. Its alloy steel construction ensures long-lasting operation, while the voltage compatibility (220-440 V) supports diverse testing setups. Whether in research labs or factory floors, this load cell delivers reliable results during critical tensile testing processes.
Expert Manufacturing and Service in India
Our expertise as a manufacturer, service provider, and supplier in India guarantees top-quality load cells tailored for industrial needs. With meticulous attention to detail, we deliver equipment that meets stringent standards. Our support staff is always available to assist with installation, calibration, and after-sales service, ensuring customers get the most out of their investment.
FAQ's of Double Ended Beam Load Cell:
Q: How is the Double Ended Beam Load Cell used in industrial tensile testing?
A: The Double Ended Beam Load Cell is integrated into tensile testing machines to measure the force applied to materials. It accurately captures tension values, enabling users to evaluate material strength and performance under stress.Q: What benefits does the alloy steel construction provide?
A: Alloy steel ensures exceptional strength, wear resistance, and a high load-bearing capacity. This durability translates into reliable data collection and a longer service lifespan, even in demanding industrial environments.Q: When should I consider using this load cell for my tensile testing process?
A: You should use this load cell when accurate force measurement and durability are critical, particularly for industrial applications involving large or repetitive loads in tensile testing.Q: Where is this load cell manufactured and whom can I contact for support?
A: This load cell is manufactured in India by an established provider specializing in industrial equipment. For assistance, you can reach out to our customer service team, who are available for installation guidance, calibration, and ongoing support.Q: What is the process for installing and calibrating this load cell?
A: Installation involves securely mounting the load cell onto the testing apparatus using provided hardware and electrical connections. Calibration is completed by applying known weights and adjusting the system output to ensure measurement accuracy, with our team available to assist at every step.Q: How does the 220-440 V operating voltage benefit my testing application?
A: This broad voltage compatibility allows the load cell to be easily integrated into various industrial setups without extensive modifications, ensuring operational flexibility and consistent performance across different facilities.
Price:
- 50
- 100
- 200
- 250
- 500
- 1000+
More Products in Load Cells Category
Heavy Duty Load Cell
Price 14000 INR / Piece
Minimum Order Quantity : 1 Piece
Usage : Industrial
Color : Silver
Product Type : Heavy Duty Load Cell
Voltage : 220440 Volt (v)
Shear Beam Load Cell
Price 12000 INR / Piece
Minimum Order Quantity : 1 Piece
Usage : Industrial
Color : Silver
Product Type : Shear Beam Load Cell
Voltage : 220440 Volt (v)
Compression Load Cell
Price 14000 INR / Piece
Minimum Order Quantity : 1 Piece
Usage : Industrial
Color : Blue
Product Type : Compression Load Cell
Voltage : 220440 Volt (v)
Stainless Steel Load Cell
Price 6500 INR / Piece
Minimum Order Quantity : 5 Pieces
Usage : Industrial
Color : Silver
Product Type : Stainless Steel Load Cell
Voltage : 220440 Volt (v)
![]() |
ARVIN INDIA
All Rights Reserved.(Terms of Use) Developed and Managed by Infocom Network Private Limited. |





Send Inquiry