Single Point Load Cell
Price 6500 INR/ Piece
Single Point Load Cell Specification
- Voltage
- 15V DC Volt (v)
- Color
- Silver
- Application
- Bench Scales
- Usage
- Industrial
- Product Type
- Single Point Load Cell
- Material
- Stainless Steel
- Type
- Single Point Load Cell
Single Point Load Cell Trade Information
- Minimum Order Quantity
- 1 Piece
- Payment Terms
- Cash Advance (CA)
- Supply Ability
- 300 Pieces Per Month
- Delivery Time
- 7 Days
- Main Domestic Market
- All India
About Single Point Load Cell
One kind of load cell that is frequently used in weighing scales and other applications that need for exact weight readings is the single point load cell. It is intended to gauge the load or force delivered at a single point of contact, usually the middle of the load cell.
Product details
|
Accuracy Class |
OIML R60 C3 |
|
Application |
Bench Scales |
|
Brand |
Flintec |
|
Cable Length |
3 Meter |
|
Capacity |
50 Kg- 250 Kg |
|
Combined Error |
<= +/- 0.0200 |
|
Compensated Temperature Range |
-10 to +40 Deg C |
|
Creep Error (30 minutes) |
<= +/- 0.0166 |
|
Features |
Low Profile |
|
Ingress Protection |
IP67 |
|
Input Resistance |
413 +/- 20 Ohm |
|
Insulation resistance at 50V DC |
>= 5000 M Ohm |
|
Load Cell Certifications |
OIML,ATEX |
|
Load Cell Intervals (nLC)/Divisions |
3000 |
|
Material |
Aluminum |
|
Maximum Excitation Voltage |
15V DC |
|
Maximum Safe Overload |
150% FS |
|
Model |
PC46 |
|
Operating Temperatue Range |
-35 to +65 Deg C |
|
Output Resistance |
350 +/- 25 Ohm |
|
Output Sensitivity(FS) |
2.0 +/- 0.1 mV/V |
|
Recommended Excitation Voltage |
5 to 15V DC |
|
Temperature Effect on Output |
<= +/- 0.0100 |
|
Temperature Effect on Zero |
<= +/- 0.0187 |
|
Ultimate Safe Overload |
300% FS |
|
Zero balance |
+/- 5% FS |
The following are some essential qualities and traits of single point load cells:
1. Single point load cells are made with a particular design that enables the application of force at a single place. Typically, they are made up of a strain gauge or several strain gauges installed on a metal structure, like aluminium or stainless steel, which stretches or contracts in response to the applied force.
2. Single point load cells come in a variety of load capacities, from a few grammes to several hundred kilogrammes or more. The load capacity reveals the heaviest object that a load cell can correctly measure.
3. Sensitivity: Due to the high sensitivity of single point load cells, they are capable of detecting even minute variations in applied force. Precise weight measurements are made possible by this sensitivity.
4. Accuracy: Single point load cells are made to measure weight with accuracy. Indicating how closely the measured weight matches the actual weight, the accuracy is often expressed as a percentage of the full-scale load.
5. Mounting: Weighing scales with a suspended platform frequently use single point load cells. They are installed in the middle of the platform, which enables a uniform distribution of the load across the load cell.
6. Applications include retail scales, industrial scales, conveyor belts, packaging equipment, checkweighers, and other weighing systems where a single point of contact is necessary. Single point load cells are widely employed in these and other applications.
7. Single point load cells can be made to endure a variety of environmental factors, including high temperatures, humidity, and corrosive environments. When choosing a load cell, take into account the precise environmental requirements of your application.
8. Calibration: To provide accurate measurements, single point load cells, like all load cells, may need periodic calibration. Application of known weights and changing the load cell's output to the expected values may be included in calibration operations.
It's crucial to choose a single point load cell that is compatible with your application's load capacity and environmental requirements. You can obtain the ideal load cell for your unique requirements by speaking with load cell suppliers or manufacturers.
FAQ
1. A single point load cell is what, exactly?
Ans - One kind of force transducer that can gauge how much force is being exerted on an item is a single point load cell. It functions by transforming the applied force into an electrical signal that may be utilised for force monitoring or measurement.
2. What kinds of settings are single point load cells suitable for?
Ans - Single point load cells have a wide range of applications, including monitoring, laboratory, and industrial settings. They are made to be accurate and dependable in settings with vibration, high humidity, and varying temperatures.
3. What are a few typical single point load cell applications?
Ans - The measurement of object size and dimensions as well as the management of tension and compression are common uses for single point load cells.
4. How can force be measured using a single point load cell?
Ans - In order to measure force, a single point load cell converts the applied force into an electrical signal. Typically, an amplifier is used to enhance this signal, a digitizer is used to turn it into digital data, and a computer or data logger is used to store and analyse the data.
5. Can single point load cells withstand hostile conditions?
Ans - Yes, severe settings are intended to be able to handle single point load cells. Even when exposed to temperature extremes, excessive humidity, and vibration, they are made to be dependable and accurate.
Engineered for Precision
Designed to deliver high-accuracy readings in industrial settings, this Single Point Load Cell is ideal for bench scales and similar applications. Its advanced engineering ensures consistent results, minimizing calibration needs and waste from imprecise measurements.
Rugged Stainless Steel Build
Constructed from premium stainless steel, the load cell resists corrosion and physical wear. The robust material ensures longevity and maintains performance even in harsh industrial environments, providing a cost-effective solution for extended usage.
FAQ's of Single Point Load Cell:
Q: How should your Single Point Load Cell be installed for optimal results?
A: To achieve the best accuracy, ensure the load cell is mounted on a flat, stable surface and properly centered under the bench scale platform. Follow the manufacturer's installation guidelines to avoid measurement errors.Q: What advantages does the stainless steel Single Point Load Cell offer for industrial applications?
A: This load cell's stainless steel construction provides superior strength and corrosion resistance, making it ideal for demanding industrial environments. It delivers reliable, long-lasting performance with minimal maintenance.Q: When is it necessary to calibrate the Single Point Load Cell?
A: Calibration should be performed during initial setup and periodically thereafter, especially if the load cell is relocated, subjected to heavy use, or after any significant mechanical impact.Q: Where can these load cells be effectively used?
A: These load cells are perfect for bench scale applications in settings like manufacturing plants, laboratories, and warehouses-anywhere precise weight measurement is critical.Q: What is the typical process for integrating this load cell with a bench scale system?
A: Begin by securely installing the load cell, then connect its electrical outputs to a compatible weighing indicator. Adjust the indicator settings per the load cell's specifications, and complete the setup by calibrating the system as required.Q: How does the 15V DC operation benefit the user?
A: Operating at 15V DC ensures stable power supply, improving signal reliability and overall accuracy during measurements, even in environments with electrical interference.Q: What are the key benefits of sourcing this product from an Indian manufacturer, supplier, and service provider?
A: Working with a local Indian supplier ensures faster delivery, dependable customer support, and access to tailored services like on-site installation and maintenance.
Price:
- 50
- 100
- 200
- 250
- 500
- 1000+
More Products in Load Cells Category
Shear Beam Load Cell
Price 12000 INR / Piece
Minimum Order Quantity : 1 Piece
Material : Stainless Steel
Product Type : Shear Beam Load Cell
Usage : Industrial
Color : Silver
Alloy Steel Load Cell
Price 11000 INR / Piece
Minimum Order Quantity : 1 Piece
Material : Nickel Alloy Steel
Product Type : Alloy Steel Load Cell
Usage : Industrial
Color : Silver
Heavy Duty Load Cell
Price 14000 INR / Piece
Minimum Order Quantity : 1 Piece
Material : Alloy Steel
Product Type : Heavy Duty Load Cell
Usage : Industrial
Color : Silver
Weighbridge Load Cell
Price 11000 INR / Unit
Minimum Order Quantity : 1 Unit
Material : Nickel Alloy Steel
Product Type : Weighbridge Load Cell
Usage : Industrial
Color : Black
![]() |
ARVIN INDIA
All Rights Reserved.(Terms of Use) Developed and Managed by Infocom Network Private Limited. |





Send Inquiry


